24
EN
cell recognition by the motor electronics in sequential mode
►
Note:
in auto close mode, the cells are recognised by the motor's electronics when auto close
mode is activated (see page 20).
deleting cells
►
If you disconnect the cells:
- in sequential mode, repeat the procedure for cell recognition by the motor electronics in
sequential mode,
- in auto closing mode, repeat the activation procedure for the automatic closing mode on
page 20.
blocking cells
►
If the cells are blocked when closing the gate, the gate will stop and reverse its movement.
If the gate is closed and the cells are blocked, the gate will not open.
safety instructions
►
The correct operation of the cells must be checked every 6 months. To do this, when the
gate is closing, block one cell with your hand.
The gate should stop and open again
.
[1].
Place a memorised 2 or 4 button
remote control on the target.
Press button 1
on the remote
control until the AUTO CLOSING
indicator
flashes.
Note:
Once step 1 has been carried
out, you can carry out the following
steps remotely (without placing the
remote control on the target).
2
3
1
x2
[2].
Briefly press button 2
on the remote
control, the AUTO CLOSE indicator
will go out then flash.
[3].
Press button 1
on the remote
control twice.