![SOMFY Freevia 280 Operating And Installation Manual Download Page 15](http://html.mh-extra.com/html/somfy/freevia-280/freevia-280_operating-and-installation-manual_1317931015.webp)
13
EN
connection to the electrical power supply
►
For your safety, these operations must be carried out with the power supply
switched off.
[1].
Strip the supply cable wires
(same length for the 3 wires).
[2].
Connect the earth wire.
An earth wire (green/yellow) and the
insulated terminal provided (17) must
be used for certain accessories (230 V
lighting Class I).
[3].
Connect the live (L) and the neutral
(N) between terminals 15 and 16 of
the electronic unit (red 230 V label).
Check that the wires are correctly
secured in place by pulling them gently
upwards.
Terminal
Blue wire
N
15
Red/brown/black wire L
16
Green and yellow wire
The colour-coding of the wires must be followed.
connection to a solar power supply
►
See page 29
safety device connection
►
cells (sold as an option in the freevia 280 pack)
See pages 22 and 23
The cells must be installed and connected before beginning to commission the motor.
orange light (sold as an option in the freevia 280 pack)
See pages 25
and 26
15
16
230V
N
P
8 mm
75 mm