background image

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

TM 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

OWNER INSTALLATION AND  

USER MANUAL Series 3000 

Models 3214, 3314, 3316 & 3414 

 

Automatic Garage Door Opener 

For Sectional Overhead Residential Doors Only 

DO NOT USE ON ONE PIECE DOORS 

 

 

 

 

 

CONTENTS 

Installation… . . . . . . . . . . . . . . . .

Wireless Keyless Entry Installation. . . . .

20 

Features… … … … … … . .  

Opening & Closing Force Adjustment…

21 

Door Tests… … … . . . . . . . . . .

 

Contact Obstruction Sensing Adjustment.

22 

Pre-Assembly Check… … … … .  

Mechanical lock Adjustment. . . . . . . . .

22 

Installation Instructions… … … …   6 

Operational Safety Rules… … …  23 

Installing Wall Station… … … . …

Operation on Your Opener… … … .

24 

Install Infrared Safety Sensors… … .  

Emergency Release Disconnect. . . . . .  26 

Wall Station Code Change  

 

Maintenance Schedule… … … . . .  27 

     and Programming… … … … .

14 Trouble 

Shooting… … … … …  28 

Infrared Safety Sensors Alignment 

16 

Parts Breakdown-Rail Assembly… …  29 

Transmitter Code Change & Programming 

16 

Parts Breakdown-Power Head Assembly.  30 

Travel Adjustment… … … … …

19 Accessories… … … … … . . .  31 

Obstruction Sensing Test… … . . .  18 

Warranty.… … … … … . . . . .

32 

Infrared Safety Sensor Obstruction Test.  19 

 

 

© Copyright 2003 Wayne-Dalton Corp.     

 

         

Part No: 307545 

 

 

 

              

New     6/18/2003

 

DOOR AND OPENER WILL NOT OPERATE PROPERLY UNTIL INFRARED SAFETY 

SENSORS ARE INSTALLED AND PROPERLY ADJUSTED!  DO NOT OPERATE DOOR 

OPENER UNTIL FULLY INSTALLED, ADJUSTED & INSTRUCTED TO DO SO! 

Before Starting Installation Read all Instructions Thoroughly  

to Familiarize Yourself with All Aspects of Installation and Adjustment!

Summary of Contents for 3214

Page 1: ...ease Disconnect 26 Wall Station Code Change Maintenance Schedule 27 and Programming 14 Trouble Shooting 28 Infrared Safety Sensors Alignment 16 Parts Breakdown Rail Assembly 29 Transmitter Code Change...

Page 2: ...nstalling or servicing a garage door sys tem Use a sturdy non metallic step ladder AFTER INSTALLATION IS COMPLETE FASTEN THIS MANUAL NEAR GARAGE DOOR PERFORM PERIODIC SAFETY CHECKS MAINTENANCE AND ADJ...

Page 3: ...E D INSTALLATION APPOSEZ L TIQUETTE RELATIVE AU D SACCOUPLEMENT D URGENCE SUR LE DISPOSITIF OU PROXIMITE DE CE DER NIER NE BRANCHEZ PAS L OUVRE PORTE AVANT D Y TRE AUTORIS PAR LA NOTICE UNE FOIS L OUV...

Page 4: ...rared reversing sensors detect an obstruction in door path and react by reversing door 9 Multi Function Wall Station Wired wall station pro vides up down door motion control and independent overhead l...

Page 5: ...nsure that the door is balanced and working properly A door that binds sticks or is out of balance could cause severe injury Do not attempt to compensate for an improperly adjusted door by the install...

Page 6: ...vices on the garage door by securing lock latch to inside face of door with suitable screw Install only on a properly balanced garage door An improperly balanced door could cause severe in jury Have a...

Page 7: ...motor end if ladder is not high enough Open the door and place a 2 x 4 piece of wood along the top sec tion of the garage door Rest the double rails on the 2 x 4 as illus trated Support the top secti...

Page 8: ...n cover to Motor Power Head Unit and push straight on until cover locks into place Note light turns on automatically when door is activated and a 4 minute time delay circuit automatically turns light...

Page 9: ...n Step 10 Install Entrapment Warning Label Install Entrapment Warning Label next to wall station in a prominent location Install Entrapment Warning Label next to Wall Station as illustrated If label a...

Page 10: ...1 2 screws supplied make sure that the curved hooks protruding from the bracket are positioned over and in firm contact with the door track Note This opener is equipped with state of the art wire less...

Page 11: ...entrapment protection It is very important that both wall brackets be mounted at the same height for proper alignment The brackets may be temporarily mounted to the jamb with a 1 flat head nail provi...

Page 12: ...n of the door and do not staple through wire Be sure to leave about 12 of excess wire at each end so you will have enough slack wire to mount units Note If wires must be lengthened or spliced into pre...

Page 13: ...elf check of the controls Check your local electrical codes If your local code requires permanent wiring use the specifications called for and in structions illustrated Permanent Wiring Procedure 1 En...

Page 14: ...tation to Power Head Unit Note Do not press any button on the wall station until instructed 1 Press the PROGRAM Switch button located on the garage door power head unit once The red PROGRAM STATUS lig...

Page 15: ...B or C on the first door transponder and set the second door trans ponder jumper to one of the other two positions A third door will use the remaining un used position Temporar ily remove the batteri...

Page 16: ...brackets are mounted at the same height see Step 9 and remount if necessary Additional minor adjustments can be made by lightly bending the mounting brackets see Figure 2 Once the alignment light come...

Page 17: ...the coin slot and twist coin to access battery compartment Some transmitters use two CR2016 or equivalent batteries while others use a single MN21 or equivalent battery Snap case together after replac...

Page 18: ...or should stop on the floor with the cushion arm and the bottom door seal slightly compressed If the door reverses off the floor turn close travel knob 1 4 turn less If door is not completely closed t...

Page 19: ...NOTE Confirm that the door has stopped in the UP position as a result of the Upper Limit Switch and not because the Trolley has hit the open Stop Bolt which is mounted in the Rail near the power head...

Page 20: ...steps using a different five digit PIN for each additional opener Step 32 Installing Wireless Keyless Entry If Included Install all wall controls out of the reach of children and in a location where...

Page 21: ...c The STATUS LED and the overhead lamp will flash on and off at a slow rate 4 Operate the door to the fully closed position 5 Turn the FORCE ADJ clockwise until the STATUS LED flickers or just turns o...

Page 22: ...act with a 1 high solid test object laid flat on garage floor and stops instead of reversing reset the door close limits according to instruction in Step 28 adjusting until door reverses upon contact...

Page 23: ...euillez lire attentivement les r gles de s curit page 3 et les instructions suivanres Faire fonc tionner uniquement lorsque l ouvre porte est correctement r gl et que la port est visible et sans obsta...

Page 24: ...sing and causes the light to flash 7 If door stops travel for 1 second at midpoint during close and then continues to close it indicates that the batteries in the Wireless Infrared Safety Sensors are...

Page 25: ...veral functions a It can be used to set a custom pet position see below b It can be used to set the opener s closing force See Adjustment 1 Page 21 To set a custom pet position start with the door in...

Page 26: ...h rapidly approx 20 sec Release both buttons Do not perform this step to train additional hand held transmitters Note This operation erases all previously trained transmitters Additional transmitters...

Page 27: ...rm safety reverse tests Step 28 and 30 Make any necessary adjustments Twice a Year Check chain tension If chain rests on bottom of rail adjust tension by turning the two chain adjusting nuts at the en...

Page 28: ...urns to fully open position and opener light flashes Door arm adjustment Close travel adjustment is set beyond normal door position Obstructions on floor Adjust rod in tube to provide 1 of cushion com...

Page 29: ...29 Parts Breakdown Rail Assembly All Models...

Page 30: ...Sensor Mounting Bracket 2 6 306486 Wiring Harness 1 20 250597 Wired Receiving Unit 1 7 269025 Light Socket 1 20a 260598 Wireless Transponder Unit 1 8 260552 Lens 1 21 260600 Wired Sending Unit 1 9 25...

Page 31: ...Can be programmed to hundreds of doors Flip lid covers key pads when not in use Multi Function Wall Control Station Part 297137 Allow independent door up down con trol and overhead light on off contro...

Page 32: ...ct returned to the Manufacturer at Buyer s expense for inspection If judged by Manufacturer to be defective in material or workmanship the product will be replaced or repaired at the option of the Man...

Reviews: