4 SBF Reference
ReceiverStatus
Number:
4014
"OnChange"
interval: 1s
The
ReceiverStatus
block provides general information on the status of the re-
ceiver.
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
Receiver time stamp, see 4.1.3
u2
1
week
65535
CPULoad
u1
1
%
255
Load on the receiver’s CPU. The load should stay below 80% in normal
operation. Higher loads might result in data loss.
ExtError
u1
Bit field reporting external errors, i.e. errors detected in external data.
Upon detection of an error, the corresponding bit is set for a duration of
one second, and then resets.
Bit 0:
SISERROR: set if a violation of the signal-in-space ICD has been
detected for at least one satellite while that satellite is re-
ported as healthy. Use the command "
lif,SisError
" for
details.
Bit 1:
DIFFCORRERROR: set when an anomaly has been detected
in an incoming differential correction stream, causing the re-
ceiver to fail to decode the corrections. Use the command
"
lif,DiffCorrError
" for details.
Bit 2:
EXTSENSORERROR: set when a malfunction has been de-
tected on at least one of the external sensors connected to
the receiver. Use the command "
lif, ExtSensorError
"
for details.
Bit 3:
SETUPERROR: set when a configuration/setup error has been
detected. An example of such error is when a remote
NTRIP Caster is not reachable. Use the command "
lif,
SetupError
" for details.
Bits 4-7:
Reserved
UpTime
u4
1
s
Number of seconds elapsed since the start-up of the receiver, or since
the last reset.
448
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...