3 Command Line Reference
3.2.16
SBF Configuration
smrf
gmrf
setMeas3MaxRefInterval
getMeas3MaxRefInterval
MaxIntrvl
OnlyRef
msec500
sec1
sec5
sec10
sec30
sec60
RxControl: Communication > Output Settings > SBF Output > Customize
Use this command to define at which interval to encode reference epochs (i.e. full measure-
ments) into the
SBF block. Refer to the description of the
block
for a definition of the reference epochs.
When generating the
SBF block, the receiver automatically selects an optimal
interval between reference epochs. This command allows the user to define the maximum
interval allowed for his application. Setting the
MaxIntrvl
argument to
OnlyRef
forces the
receiver to only encode reference epochs in
. This will allow to decode all
epochs independently of any previous epoch, at the expense of a larger average SBF block
size.
Example
COM1>
smrf, OnlyRef<CR>
$R: smrf, OnlyRef
Meas3MaxRefInterval, OnlyRef
COM1>
214
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...