4 SBF Reference
MeasExtra
Number:
4000
"OnChange"
interval: internal measurement rate (receiver-type depen-
dent)
This block contains extra information associated with the measurements contained in the
MeasEpoch
block, such as the internal corrections parameters applied during the measure-
ment pre-processing, and the noise variances.
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
Receiver time stamp, see 4.1.3
u2
1
week
65535
N
u1
Number of sub-blocks in this
block.
SBLength
u1
1
byte
Length of a sub-block
DopplerVarFactor
f4
1
Hz
2
/ cycle
2
Factor to be used to compute the Doppler variance from the
carrier phase variance. More specifically, the Doppler variance in
mHz
2
can be computed by:
σ
2
Doppler
[mHz
2
] =
CarrierVariance
*
DopplerVarFactor
,
Where
CarrierVariance
can be found for each measure-
ment type in the
MeasExtraChannelSub
sub-blocks.
ChannelSub
...
...
A succession of N
MeasExtraChannelSub
sub-blocks, see defini-
tion below
Padding
u1[..]
Padding bytes, see 4.1.5
307
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...