3 Command Line Reference
ssm
gsm
setStandbyMonitoring
getStandbyMonitoring
StandbyPeriod
0 . . . 15724800 s
RxControl: File > Power Mode > Monitoring
This command is to be used in conjunction with the
command.
It specifies the sleep duration when the supply voltage drops below the level set with
When the supply voltage (e.g. from an external battery) drops below the threshold set with
, the receiver enters low-power sleep mode for a duration given by
the
StandbyPeriod
argument. At the end of this duration, the receiver wakes up and either
resumes operation normally if the supply voltage is sufficient, or otherwise returns into sleep
after about 30 seconds for a new
StandbyPeriod
duration.
This power-monitoring and -saving feature is enabled if both the
StandbyPeriod
argument of
this command and the
ExtPowerSupply
argument of the
command
are different from zero.
Note that power monitoring can be enabled together with the scheduled sleep feature (see
the
command). In that case, the scheduled-sleep pattern will be interrupted
for at least
StandbyPeriod
when the supply voltage drops under the threshold.
Example
If you want the receiver to go to sleep for an hour each time the external power supply drops
below 11.4V, use:
COM1>
ssm, 3600 <CR>
$R: ssm, 3600
StandbyMonitoring, 3600
COM1>
spth, 11.4 <CR>
$R: spth, 11.4
PowerThresholds, 11.4
COM1>
eccf, Current, Boot <CR>
$R: eccf, Current, Boot
CopyConfigFile, Current, Boot
COM1>
99
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...