3 Command Line Reference
sc2o
gc2o
setCMRv2Output
getCMRv2Output
Cd
Cd
Messages
+ COM1
+ COM2
+ COM3
+ COM4
+ USB1
+ USB2
+ IP10 ... IP17
+ NTR1
+ NTR2
+ NTR3
+ IPS1
+ IPS2
+ IPS3
+ IPS4
+ IPS5
+ IPR1
+ IPR2
+ IPR3
all
none
+ CMR0
+ CMR1
+ CMR2
+ CMR3
all
RxControl: Communication > Output Settings > Differential Corrections > CMRv2
Use these commands to define/inquire which CMR v2.0 messages are enabled for output
on a given connection descriptor (
Cd
- see 1.1.5 ). The
Messages
argument specifies the CMR
message types to be enabled. Refer to appendix D for an overview of the supported CMR
v2.0 messages.
Please make sure that the connection specified by
Cd
is configured to allow CMRv2 output,
which can be done with the
command. The interval at which each message
is output is to be specified with the
command.
Example
To enable CMR v2.0 message 0 on COM2, use the following sequence:
COM1>
sc2o, COM2, CMR0 <CR>
$R: sc2o, COM2, CMR0
CMRv2Output, COM2, CMR0
COM1>
sdio, COM2, , CMRv2 <CR>
$R: sdio, COM2, , CMRv2
DataInOut, COM2, auto, CMRv2
COM1>
246