Hysteresis
decimal
The amount by which the measured
value has to drop below the threshold
to re-enable the event.
-1000 to
1000
°C
tc1.hysteresis
Type
text
Determines the type of thermocouple
connected. Valid values are: K, J, T, N, S,
E, B and R
1 chars
tc1.type
Warning
text
Warning thresholds. Refer to user
guide.
-1000 to
1000
°C
tc1.warning
Alarm
text
Alarm thresholds. Refer to user guide.
-1000 to
1000
°C
tc1.alarm
CAN 1
Name
text
A name that is meaningful to the user.
25 chars
can1.name
Interval
integer
The number of base intervals after
which the CAN module is turned on.
Set to 0 to disable.
0
to
10000
can1.interval
Nominal
Baud Rate
integer
Baud rate for CAN communication.
Supported values are: 125, 250, 500,
1000
kbit/s
can1.nominal_baud
Capture
Time
integer
The device will capture matching
messages for this length of time.
Seconds
can1.capture_time
TX Enable
boolean
Allows the device to transmit and
acknowledge messages on the CAN
bus.
can1.tx_enable
ID Capture
List
text
List of IDs to be captured in HEX
format, separated by a comma eg:
18FEE60A. Leave blank to capture all.
200
chars
can1.id_list
CAN 2
Name
text
A name that is meaningful to the user.
25 chars
can2.name
Interval
integer
The number of base intervals after
which the CAN module is turned on.
Set to 0 to disable.
0
to
10000
can2.interval
Nominal
Baud Rate
integer
Baud rate for CAN communication.
Supported values are: 125, 250, 500,
1000
kbit/s
can2.nominal_baud
Capture
Time
integer
The device will capture matching
messages for this length of time.
Seconds
can2.capture_time
TX Enable
boolean
Allows the device to transmit and
acknowledge messages on the CAN
bus.
can2.tx_enable
ID Capture
List
text
List of IDs to be captured in HEX
format, separated by a comma eg:
18FEE60A. Leave blank to capture all.
200
chars
can2.id_list
Current
Loop 1
Name
text
A name for the input that is meaningful
to the user.
25 chars
current1.name
Interval
integer
The number of base intervals after
which the input is sampled. A value of
1 means that the input is collected every
base interval. Set to 0 to disable.
0
to
10000
current1.interval
ORB User Guide, Release 1.1
6.7. External Sensor Settings
75
Summary of Contents for ORB-X1-G
Page 1: ...ORB User Guide Release 1 1 Senquip Sep 14 2020...
Page 2: ......
Page 16: ...ORB User Guide Release 1 1 10 Chapter 1 Introduction...
Page 44: ...ORB User Guide Release 1 1 38 Chapter 3 Power Supply...
Page 50: ...ORB User Guide Release 1 1 44 Chapter 4 General Setup...
Page 86: ...ORB User Guide Release 1 1 80 Chapter 6 External Sensors...
Page 92: ...ORB User Guide Release 1 1 86 Chapter 7 Network Connection...
Page 98: ...ORB User Guide Release 1 1 92 Chapter 8 Endpoint Setup...
Page 116: ...ORB User Guide Release 1 1 110 Chapter 10 Mechanical Speci cation...
Page 130: ...ORB User Guide Release 1 1 124 Chapter 12 Troubleshooting Guide...
Page 134: ...ORB User Guide Release 1 1 128 Index...
Page 136: ......