10. TECHNICAL DATA
SENKO cooker
C-20 2P
C-30 2P
Nominal heat output
, kW
25
35
Boiler
, kW
16
20
Room
, kW
9
15
Amount of water in boiler
,
L
20
28
Operating pressure (max)
, bar
3
Operating temperature
, °C
85
Width
, mm
1400
Depth,
mm
680
815
Height,
mm
850/1255
Weight,
kg
450
520
Firebox opening (W × H)
,
mm
200×260
Firebox (W × D)
, mm
275×430 275×570
Firebox volume
, dm
3
62,08
82,29
Fuel consumption
, kg/h
9
10
Height of grate lifting
, mm
175
165
Cooking plate (W × D)
, mm
595×465 595×595
Cooking plate area
, m
2
0,276
0,354
Oven (width)
, mm
330
Oven (height)
, mm
220
Oven (depth)
, mm
440
550
Ash pan
, L
7,5
10,5
Fuel box
, L
31,6
Flue gases exhaust
, mm
150
Flue gas temperature
, °C
250
270
Required flue draught
, Pa
12
16
CO in flue gases at
13% O
2
, %
0,5
0,56
Flue gas mass flow rate
, g/s
17
33,6
Efficiency
, %
75
75,5
Regulation
Primary air
automatic
Secondary air
Manufactured in accordance with EN norm
EN 12815
-
technical specification apply to wood and wooden briquettes used as fuel
-