SENKO cookers 2P extra rustik and glass
–
Instruction manual
26
5.2.
AIR ADJUSTMENT AND REGULATION
CHIMNEY
If the chimney is equipped with a vent damper, it must be adjusted to keep
the
chimney flue draught within the limitations
:
for C-20 2P
12 ± 2 Pa,
for C-30 2P
15 ± 2 Pa.
PRIMARY AIR
Primary air is the air that flows directly
through the firebox grate
. There is an
automatic
primary air regulator
(12) between the fuel box
(15) and ash box (14). Its probe, which measures
the temperature of the water in the boiler, is placed
on the boiler frontal side under the lid, between
upper and lower door.
Turning the PVC wheel of the automatic regulator
regulates primary
air flow
. Regulator is set in accordance with the desired boiler water
temperature. The division ranges
from min
(thin end of the semicircle)
to
max
(wide end of the semicircle) :
min
automatic regulator is closed and there is no primary air
flow,
max
primary air opening is completely open and the flow is at its
maximum.
min
max
figure 15