SENKO cookers 2P extra rustik and glass
–
Instruction manual
7
1.3.
CHIMNEY
The cooker is connected to the chimney via
150 mm diameter sliding
rosette.
It is necessary to execute the connection of the rosette and the
chimney tightly and impermeably.
If the cooker is separated from the
chimney opening
(not recommended) the connection is made via
standard 150 mm diameter smoke venting pipe.
We also advise
to
equip the chimney with solid material and
possible condensation products collection chamber
and to install the
chamber in question beneath the smoke channel inlet, in a manner which
allows easy access and inspection via impermeable door.
1.3.1. CHIMNEY CAP
Chimney cap must fulfill the following prerequisites:
identical internal cross-section
to that of the chimney,
operational
exit cross-section no less than the double inner
cross-section of the chimney
,
constructed
to prevent rain, snow, leaves and other foreign
bodies from entering
the chimney,
constructed
to enable expulsion of combustion products in
case of wind
from any direction and incline,
installed
to enable proper dispersion and dilution of
combustion products outside the reflux zone
(backflow)
because the counter pressure occurs here. Therefore, it is
necessary to adhere to limitations listed in
figure 2
,
mechanical appliances for flue gases suction are not allowed
.