SENKO cookers 2P extra rustik and glass
–
Instruction manual
38
direction
upper or lower door
opened
inadequate flue
draught
faulty regulation
adjust the flue draught in
accordance with chapter 4.2.
adjust the primary and secondary
air in accordance with chapter 5.2.
Smoke coming out of
the cooker
cooker filled with
soot
chimney filled with
soot
fuel too moist
low calorie fuel
levels of fresh air in
the room too low
return water
temperature too low
firebox temperature
too low
chimney lower than
4.5 m
chimney diameter
smaller than the one
prescribed
clean the cooker as described in
chapter 6.
clean the chimney as described in
chapter 6.
use fuel as described in chapter 1.1.
study chapter 4.4.
set the thermostat to activate the
pump at temperatures over 60
C
increase the firebox temperature by
increasing fuel quantity
adjust the chimney in accordance
with chapters 4.2. and 4.3.
Water leaking from the
boiler (boiler
condensation)
excessive water flow
fuel too moist
boiler damaged
insufficient fuel
quantity
insufficient primary
air volume
reduce the water flow
use fuel as described in chapter 1.1.
call an authorized maintenance
technician
add more fuel to the firebox
increase primary air volume in
accordance with chapter 5.2., check
the functionality of the primary air
automatic regulator
Cooking and baking
temperature too low
insufficient or
excessive chimney flue
draught
excessive primary air
volume
inadequate fuel
too much fuel
–
combustion difficult
flue gas deflector
opened
grate too low during
summer period
adjust the chimney flue draught in
accordance with chapter 4.2.
reduce primary air volume
use fuel as described in chapter 1.1.
add less fuel to the firebox
close the flue gas deflector
set the grate into the upper position
(for C-30 2P), i.e. set the height as
desired (for C-20 2P)
Cooking and baking
temperature too high
excessive chimney
flue draught
inadequate fuel
flue gas deflector
closed
grate too high during
summer period
reduce the chimney flue draught in
accordance with chapter 4.2.
use fuel as described in chapter 1.1.
open the flue gas deflector
lower the grate