Outlet boiler water does
not reach the required
temperature
central heating
system improperly
dimensioned
insufficient fuel
quantity
central heating
system thermometer
does not display the
temperature properly
dimension the central heating
system according to professional
standards and DIN 4751 norm
– part 1
for open systems, i.e. DIN 4751
– part
2 for closed systems
adjust the water flow in accordance
with the boiler thermal possibilities
add more fuel to the firebox in
accordance with chapter 5.4.2.
install functional and approved
(moderate) thermometer
Raising or lowering the
grate somewhat difficult
non-combustible
material debris
between the grate and
the boiler (nails and
similar)
malformed boiler
thoroughly clean the non-
combustible material debris
call an authorized maintenance
technician
9. TECHNICAL SUPPORT
Dear client,
If you were unable to find the solution to the malfunctions, that potentially
developed while using your product, in the table above, please feel free to
contact our complaint and support service:
Tel.: +385 (0)40 337 344
Fax.: +385 (0)40 337 906
E-Mail:
WE’D LIKE TO TAKE THIS OPPORTUNITY TO REMIND YOU WHAT
YOU NEED TO POSSES WHEN CONTACTING OUR COMPLAINT AND
SUPPORT SERVICE :
Before you contact us, prepare the following documents :
purchase receipt with the date of purchase
,
warranty
(at the back of this
Manual
),
written installation report
(at the back of this
Manual
),
Instruction manual
.
The documents listed above are necessary to ensure the quickest and
clearest removal of the occurring malfunction!