SENKO cookers 2P extra rustik and glass
–
Instruction manual
14
4.2.
CHIMNEY PREPARATION AND CONTROL
Prior to cooker mounting, it is necessary to check the chimney
– the
diameter, height, possible clogging or damages. The chimney must be
certified by an authorized local chimney-sweeper.
The effective
chimney height
must be
at least 5 meters
from the point of flue gases
outlet (
figure 7b
).
Flue draught
must be within parameters:
for C-20 2P
12 ± 2 Pa,
for C-30 2P
15
± 2 Pa.
The chimney must be
at least 0,5 meters above the roof ridge. The
minimum distance between the two connections on the same chimney
must be 60 cm
(
figure 7d
).
Chimney diameter is chosen according to information provided by the
chimney manufacturer
– e.g., for flue draught of 15 Pa, the diameter is
usually 160 mm.
The chimney must be smooth on the inside, well insulated and well
fastened
. All cleaning hatches must be well fastened. All gaskets must be
regularly inspected and replaced when necessary.
4.3.
CONNECTING TO CHIMNEY
When connecting the cooker to the chimney it is necessary to adhere to
local, national and European regulations (norms)
–
DIN 4705
.
It is necessary to ensure that
the connection between the cooker and
the chimney is executed tightly and impermeably
. Smoke outlet pipe
must have
a suitable incline in cases where the cooker is removed
from the chimney opening
.
Smoke outlet pipe must not penetrate into the chimney clear
opening
(
figure 7c
).
Differences between the proper and improper connection of the cooker
to the chimney are displayed in the following figure.