SENKO cookers 2P extra rustik and glass
–
Instruction manual
13
4. INSTALLATION
Once you have removed packaging from the cooker, it is necessary to
make a detailed inspection in order to determine any potential
damages
that might have occurred during transport. Nay detected
damages must instantly be reported to the manufacturer.
In places of any connection points on the cooker (water, thermal
protection, chimney, air inlet),
inspection hatches must be installed for
system maintenance and servicing purposes.
4.1.
POSITIONING
A spirit level must be used to place the cooker in a horizontal
position with no incline
. It is necessary to ensure
the minimum distance
of the cooker from any flammable objects
; such as wood, chipboard,
cork and similar. If the materials are easily combustible such as PVC,
polyurethane and similar, the necessary safety distances need to be
doubled.
The minimum distance from any flammable surfaces
above and in
front of the cooker is 800 mm, and 200 mm in all other directions.
When mounting the cooker on the floor made from easily combustible
material (
wooden floors
), the cooker must be
mounted on an insulating
non-combustible surface
, 60 mm thick. The surface must cover the layout
area of 800 mm in front of the cooker and 400 mm in all other directions.
It is explicitly RECOMMENDED by the manufacturer to place the
cooker as close as possible to the chimney hole, i.e. next to the
chimney hole itself in order to avoid using an additional smoke uptake
pipe. If the additional smoke uptake pipe is not used, maximum
efficiency of the cooker, i.e. fuel is additionally assured !