ERROR 100: Management Chip, reader/writer error
[DISPLAY] ERROR 100
RFID READER NOT READY
(If the error occurs in Test Mode, “READER NOT READY” is displayed)
[CAUSE]
The wire connection is not properly configured, or there may be a broken wire or
damaged hardware.
[COUNTERMEASURES] Turn off the power, check the wire connection, and then restart the
machine. If the problem still persists, the machine may be damaged.
Replace broken parts with new ones.
ERROR 101: Management Chip read error
[DISPLAY] ERROR 101
RFID READ ERROR
(If the error occurs in Test Mode, “READ ERROR” is displayed)
[CAUSE]
(1) The wire connection is not configured properly, or there may be a broken wire
or damaged hardware.
(2) The Management Chip is not inserted properly in the slot.
[COUNTERMEASURES] (1) Turn off the power, check the wire connection, and then restart
the machine. If the problem still persists, the machine may be
damaged. Replace broken parts with new ones.
(2) Check the status of the Management Chip and reinsert it. The
chip may be damaged. Replace it with a new one if necessary.
ERROR 102: Management Chip write error
[DISPLAY] ERROR 102
RFID WRITE ERROR
[CAUSE]
The process of writing data to the Management Chip does not complete properly.
The verified data does not match the results of the data check. The Management
Chip is not inserted properly in the slot.
[COUNTERMEASURES] Reinsert the Management Chip properly. If the problem still persists,
the chip may be damaged. Replace it with a new one.
ERROR 103: Management Chip decrement error
[DISPLAY] ERROR 103
RFID DECREMENT ERROR
[CAUSE]
The process of credit reduction does not complete properly. The counter does not
decrease by 1 after the reduction process. The Management Chip is not inserted
properly in the slot.
[COUNTERMEASURES] Reinsert the Management Chip properly. If the problem still persists,
the chip may be damaged. Replace it with a new one.
7−2 MANAGEMENT CHIP ERROR CODES
When problems occur with the Management Chip, the following error codes will be displayed
on the screen. Refer to the “cause” and “countermeasures” list below in order to deal with the
problem appropriately.
The following error codes will not be displayed if either the Management Chip or the reader/writer
is functioning properly.
Summary of Contents for Dinosaur King
Page 3: ......
Page 110: ...105 105 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC UNIT DKT 4100 D 1 2...
Page 118: ...113 113 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1...
Page 120: ...24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 24 114 23 WIRING DIAGRAM D 1 2...
Page 121: ...24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 115 23 WIRING DIAGRAM D 2 2...