General instructions for safety, assembly, commissioning, usage and maintenance 

 

to be read before working on the device 

I. GENERAL 
These instructions must be read jointly with: 
+the standard NFC15-100 
+the technical data sheet specific to the device 
The  Sefram  devices  are  designed  to  be  assembled, 
commissioned  and  used  in  compliance  with  the 
characteristics/data  given  in  the  technical  data  sheet. 
Always adhere to all of directives, legislation, orders and 
most  recent  standards  in  force  for  the  stated  field  of 
application. 
The assembly, commissioning, usage and maintenance 
operations  must  always  be  carried  out  by  qualified  and 
authorized personnel.  
Personnel working on the devices must be familiar with 
the safety rules and requirements in force regarding the 
components, 

devices, 

machines 

and 

electrical 

installations. 
II. RECEPTION - STORAGE 
After unpacking the device, check that this latter has not 
been  damaged  during  transport;  for  certain  devices, 
remove the protective film from the cover. The material 
must be stored inside in a dry place. 
In the event of a problem, please contact Sefram. 
III. ASSEMBLY  
The  assembly  operations  must  be  carried  out  by 
qualified,  skilled  and  authorized  personnel.    Personnel 
working  on  these  devices  must  be  familiar  with  the 
safety rules and requirements in force.   
The box must be mounted vertically. 
For  material  connected  permanently  to  the  network,  a 
quickly  accessible  cut-off  device  must  be  incorporated 
into the cabling installation of the building. 
The  device  supply  must  be  equipped  with  a  device  for 
protection  against  risks  of  over-current  and  fault 
isolation.    The  number  of  poles  protected  must  be 
appropriate  to  the  neutral  regime  of  the  building  and  to 
the regulations in force. 
The equipment must be connected to the PE protection 
mass by green/yellow wires (NFC15-100). 
The  device  is  compatible  with  the  neutral  regimes  TT, 
TN or IT; 
Nevertheless,  we  recommend  that  the  device  is 
supplied  through  the  intermediary  of  an  insulation 
transformer  for  which  the  primary  is  supplied  between 
phases  and  not  between  phase  and  neutral,  so  as  to 
avoid  any  accidental  over-voltage  caused  when  the 
neutral is cut before the phases.  
In the event of a problem, please contact Sefram. 
 

 

 

IV. COMMISSIONING AND USAGE 
Commissioning  is  authorized  only  after  duly  establishing 
that the device, the machine or the installation in which the 
device  has  been  integrated  in  a  compliant  manner, 
satisfies  all  of  the  directives,  legislation,  orders  and  most 
recent standards in force.  
Commissioning  operations  must  be  carried  out  by 
qualified,  skilled  and  authorized  personnel.  Personnel 
working  on  these  devices  must  be  familiar  with  the  safety 
rules and requirements in force.  
Note:  correct  operational  functioning  does  not  in  itself 
constitute 

an 

indication 

of 

conformity 

to 

the 

recommendations  for  the  use  of  the  material  in  complete 
safety.   
Also  read  the  maintenance  recommendations  which 
equally apply during commissioning and use.  
In the event of a problem, please contact Sefram. 
V. MAINTENANCE 
The device does not require any special maintenance. 
The  following  operations  are  recommended;  they 
constitute a minimum: 

Before  any  work  intervention,  we recommend that 

the dust is removed before opening the cover, 

The  device  must  not  be  opened in an excessively 

dusty environment, 

The  integrity  of  the  joints  must  be  checked: 

remove any trace of dust or other deposit, 

Remove  any  trace  of  dust  which  could  have 

penetrated during the setting operation, 

Always ensure that the cover is correctly closed. 

To  maintain  accuracy  of  measurement, an annual 

calibration  is  recommended  especially  at  "zero"(see 
calibration). 

Replacement  of  fuses  must  be  carried  off  the 

power, taking care to respect the caliber of each fuse 
 
 
Maintenance  operations  must  be  carried  out  by  qualified, 
skilled  and  authorized  personnel.    Personnel  working  on 
these  devices  must  be  familiar  with  the  safety  rules  and 
requirements in force.  
In  the  event  of  a  problem  or  any  questions  during  these 
operations please contact SEFRAM.

 

 

 

Summary of Contents for Sequencer COMPACT

Page 1: ...hnical brochure FI 72 0467 0118E Page 1 42 PLACE GUTENBERG 59175 TEMPLEMARS France Tel 33 0 3 20 60 49 49 Fax 33 0 3 20 95 59 62 Email contact sefram eu Web www sefram eu Electronics dedicated to dedu...

Page 2: ...nning faults dust and pressure measures are clearly displayed A graphic representation of pressure dust rejection and analog input allows an easy control of their level An USB key can be plugged to th...

Page 3: ...48Vac 115Vac 230Vac voltage to supply According to power and voltage of the solenoid valve TOUCH SCREEN Size Technology 4 3 inches TFT LCD Tactile Resistive Resolution Colors 480x272 pixels 65536 colo...

Page 4: ...n mounting on support RAIL DIN Dimension of display 129 x 103 x 39mm L x l x P Window 118 8 x 92 8mm L x l CONNECTIONS PRESSURE Pressure pipe to be connected to the sensor Polyurethane tube 4x2 5mm Tu...

Page 5: ...f supplies in case of a failed SV short circuit There is 1 common fuse for the 16 outputs This fuse is on the corresponding output card Version DC Version AC The fuse rating depends on order tension o...

Page 6: ...Link to sequencer card Output Relay running order response Output Relay Alarm analog input High Alarm Low Alarm or fault Output Relay General fault Output Relay High alarm dP Inputs TOR Run order Comp...

Page 7: ...ust control sensor CDM Link to Sequencer card Link to sensor with 4 20 output as a temperature sensor dP measure output GENERAL DEFAULT OUTPUT If default is present contact between C and NC HIGH dP AL...

Page 8: ...ACT Technical brochure FI 72 0467 0118E Page 8 42 Connections Sequencer DC card Link to mother card RS485A output with SQ A input RS485B output with SQ B input Power supply 24Vdc Order outputs SV 24Vd...

Page 9: ...Sequencer COMPACT Technical brochure FI 72 0467 0118E Page 9 42 SEQUENCER CARD DC CONNECTION Example 16x Solenoids valves outputs 24Vdc 25W Card n 0 Link to MOTHER Card Card n 0 SV1 to SV16...

Page 10: ...e FI 72 0467 0118E Page 10 42 Connections Sequencer DC card Supply Voltage 24Vdc Supply voltage SV AC PHASE Order output SV from 1 to 16 Supply VAC NEUTRAL Link to mother card RS485A output with SQ A...

Page 11: ...Sequencer COMPACT Technical brochure FI 72 0467 0118E Page 11 42 SEQUENCER CARD AC CONNECTION Example Card n 0 Card n 0 SV1 to SV16 16x Solenoids valves Vac outputs...

Page 12: ...link towards informations page of CDM Measure of dust rate This display is ON only if a dust sensor has been validated into parameters Configuration of the dust sensor is available on Parameters Menu...

Page 13: ...s automatically reset but for some others it is necessary to reset them manually page current defaults Note If the present display page is different than the main page and if a new default appears we...

Page 14: ...COMPACT Technical brochure FI 72 0467 0118E Page 14 42 Page Current Defaults 1 list of the present defaults with time 2 link towards general main page 3 link towards main page synoptic 4 default rese...

Page 15: ...able at level 0 1 and 2 To reset manufacturer counter press Reset area enable at level 2 6 Press the button to display the manufacturer counter or user counter If manufacturer is displayed the counter...

Page 16: ...e max is set at value 0 This value will be updated when the first max value is observed There is no max value during 3 seconds after the start of declogging cycle 3 Mini load loss measured dP daPa To...

Page 17: ...e is adjustable between 1 to 60 sec see on pressure switch page parameters Example if the sample rate setting is 1 record 60sec then the total recording time is equal to 138 days To insert the USB key...

Page 18: ...have a good knowing of this sensor CDM Sensor to monitor dust emission FI 72 0401 0115E 1 Instantaneous of dust emission rate Value in regarding the alarm threshold Alarm threshold n2 x PR value 2 Mea...

Page 19: ...on on the USB key The sample rate is adjustable between 1 to 60 sec see on Dust Sensor CDM page parameters Example if the sample rate setting is 1 record 60sec then the total recording time is equal t...

Page 20: ...s measures on the USB key The sample rate is adjustable between 1 to 60 sec see on Pressure Switch page parameters Example if the sample rate setting is 1 record 60sec then the total recording time is...

Page 21: ...e 2 link towards Password Setting 3 link towards menu parameters HMI 4 link towards menu languages 5 link towards menu manual mode Setting enabled in level 1 2 6 link towards menu information 7 link t...

Page 22: ...esponds to the manufacturer level allowing to add or cancel functions to the system as well as to adjust parameters of these functions Allow to record some measure dP dust emission analog input and de...

Page 23: ...MI settings 1 Setting of the clock 2 Calibration of the size of the screen Necessary when the touch screen does not react precisely 3 Adjustment of the lightning of the screen 4 Link towards main page...

Page 24: ...42 Page Language settings 1 english 2 Indonesian 3 french 4 language in use 5 link towards page general menu 6 link towards main page synoptic To modify the language in use of the system press the co...

Page 25: ...g cycles following the settings in the controller part number of SVs and duration of times of the cycle The declogging cycles in manual mode are enabled whatever will be the status of running order in...

Page 26: ...System 1 identification of the manufacturer supplier 2 name of the device 3 serial number of the box 4 name of software version identification of software electronic card identification of software H...

Page 27: ...the HMI Once USB key is inserted wait the audio signal which indicates that the system has identified the USB key Press USB recording key validate and wait for the message successful recording recordi...

Page 28: ...u Dust sensor CDM parameters 4 link towards menu Pressure switch parameters 5 link towards menu analog input 4 20mA parameters name of the analog input 4 20mA which is documented in the page analog in...

Page 29: ...nning order not present if value of the load loss dP is smaller than the fan stop threshold 2 This setting is displayed if the detection of the fan stop is set by a low dP value The Fan Stop is detect...

Page 30: ...the cycle will stop where it is at the end of T2 time It will start again from this position 3 Enslavement of declogging with load loss dP 2 possible choices setting enabled in level 2 with dP declogg...

Page 31: ...LE Resting time between 2 declogging cycles Adjustable from 0 to 255 minutes setting enabled in level 1 2 0 inactive 5 T4 AUTO CYCLE If the sequencer did not have declogging cycle during the defined t...

Page 32: ...in level 1 2 3 Adjustment of value n2 from 2 to 33 x PR setting enabled in level 1 2 4 Adjustment of time X from 1 to 33 minutes setting enabled in level 1 2 5 Self learning of the mean dust emission...

Page 33: ...al running 4 High Alarm dP threshold Adjustments from 0 to 500 daPa setting enabled in level 1 2 If dP measure exceeds this threshold more than 5 seconds High Alarm dP If dP measure falls below this t...

Page 34: ...ation of the analog input 5 value of the measured physical value corresponding to the value of the input 4 20mA 4mA see notice of the instrument which is connected to the analog input setting enabled...

Page 35: ...rocess Modbus link is used 2 speed setting 4800 9600 19200 38400 51200 115200 Bauds setting enabled in level 1 3 Number of stop bit setting 1 2 setting enabled in level 1 4 Parity setting Without Even...

Page 36: ...than the alarm threshold which is adjusted in page parameters CDM0 see CDM brochure none on the running check the integrity of filters CDM Alarm Configuration YES Alert and or Alarm threshold is out o...

Page 37: ...onic board If there is at least one fault except the information maintenance number of cycles overpassed the information general fault is given the relay is powered if there is no fault Reset of fault...

Page 38: ...ode If fan stop is detected by load loss measure dP If running order input is off I1 0 the sequencer stops immediately or finishes the ongoing cycle according to the chosen mode If fan stop is noted t...

Page 39: ...y off if fault present Relay REL2 high dP alarm Relay supplied if no high dP alarm Relay off if high dP alarm Relay REL3 analog input alarm Relay supplied if no analog input fault and no high dP alarm...

Page 40: ...e cable for specific exploitation conditions consult us interventions must always be done by a qualified person CALIBRATION When the device leaves our workshop it is adjusted at 0 value for the zero p...

Page 41: ...T TN or IT Nevertheless we recommend that the device is supplied through the intermediary of an insulation transformer for which the primary is supplied between phases and not between phase and neutra...

Page 42: ...except connections and adjustments In case of failure intervention is not allowed and the device must be sent back at the following address CONFORMITY The sequencer COMPACT is in accordance with the E...

Reviews: