ProLogic L66
Operation Instructions
47
Step 5: The system will prompt you to enter the Manufacture Code. Enter 975246 (PW L
6/Users 10 or PW L 6/Users 30) or 97524600 (PW L 8/Users 30) and press OK.
The system will now cycle the motor drive system, locking and unlocking the lock body every 1.5
seconds. The cycle testing will continue until the battery depletes itself of energy or power is
removed.
17.2 Hardware Testing
The “Hardware Testing” menu selection is not available for field use. However, it is used in the
manufacturing process to check the board level components.
18.0 Menus
There are two menus on the ProLogic L66, the root menu and a sub-menu.
The sub-menu is accessible by entering a valid code. The menu selections in the sub-menu change
depending upon the level of the code entered. Super Code (ID00), and Manager Codes (ID01 and 02)
have access to the all programming menus. User Codes have limited menu selections.
ProLogic L66 Menu
Root Menu
Select Menu
System Menu
System Info
Show Clock Time
Recovery Code Set
Recover System
Encryption Key Set
Sub Menu – Super/Manager Codes
Select Menu
Change Code
Show Audit Trail
Wireless Connection
System Info
Show Clock Time
Day Light Savings TM
Set Clock Time
See Timer
Set Timer
Set Time Table
Set Holidays
Max Door Open Time
Set TDO User ID
Set Duress Time Delay
Set/Cancel Time Delay
Obfuscate Code Entry
Set ID 01 To Master*
Delete All Users
Set Number of Locks
Recovery Code Set
Recover System
Encryption Key Set
Set Device ID Number
Set Host ID Number
Restore Data