3
Step 4: Using a paper clip depress the reset button, inside the reset hole, 3 times to dissipate
any latent energy in the lock.
Step 5: Now depress the reset button and hold.
Step 6: While continuing to depress the reset button, connect the lock cable to the lock body.
Step 7: Continue to hold down the reset button for 5 seconds and then release.
Step 8: Verify that the pairing has been completed, by opening the lock with the default code
111111.
Step 9: Press any button on the EntryPad to initiate a lock communication test. The EntryPad
will display the following information:
Followed by:
Enter a valid code to test the lock.
The Default codes are as follows:
Super Code (ID00) is 111111
Manager Code (ID01) is 123456
Upon entry of a valid code, the lock will open. If the lock does not open and the LCD screen
displays the message “Fail to Link with Lock”, repeat the reset procedure. Be sure to hold down
the reset button through steps 5-7.
If you have difficulty resetting the lock, please call SecuRam Tech Support at (805) 988-8088 or email
.
1.3 Lock and EntryPad Installation
Included within your installation kit are (2) shoulder bolts and (3) lock mounting bolts.
Install the shoulder bolts on the safe door in the pre-drilled holes above and below the spindle
hole.
Now insert the lock cable (attached to the EntryPad) through the spindle hole.
On the backside of the safe door, you will see the lock mounting plate and the predrilled lock
mounting holes.
Connect the lock cable to the lock body and position the lock body appropriately on the lock
mounting plate.