Advises
Problem F
ound
Possible
Make sure all Safety LED are turned ON
TROUBLE SHOOTING
All not-used N.C. Contacts must be bridged
Cause
Solutions
The motor doesn’t
respond to any START
impulse
a.)
Bridge missing on one of the
N.C. contacts
b.)
Burnt fuse
a.)
Check connections or bridges
on contacts 2/6 on the Cn1, 2/7 on
the Cn1
b.)
Replace burnt fuse on the board
Gate doesn’t move
while the motor is
running
a.)
The motor is in the released
position
b.)
Trimmer Rv1 is at minimum
c.)
There is an obstacle or an
obstacle is detected but it is not
really present
a.)
Re/lock the motor
b.)
rotate Trimmer Rv1 at maximum
(rotate clockwise)
c.)
Look and remove the obstacle
If encoder function is on, decrease
its sensitivity
Gate doesn’t reach
the complete
open/close position
a.)
Programming error
b.)
Gate is stopped by an obstacle
c.)
The fiting geometry is
inadequate
d.)
In manual adjusting mode with
trimmer Rv4
a.)
Repeat the programming
b.)
Remove the obstacle
c.)
Check fitting geometry following
the operator installation manual.
d.)
Rotate Trimmer Rv4 clockwise
Gate opens bur
doesn’t close
a.)
Photocells connections 2/6 and
2/7 are not closedi
a.)
Check LED or bridges
Gate doesn’t close
automatically
a.)
Pause time is too long
b.)
The setted operating logic
doesn’t include it
a.)
Adjust the pause time using
Trimmer Rv3
b.)
Check dip1 and Trimmer Rv3 in
order to verify the setted logic
SWING 2
37
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
REV 07 - 05/2009