OPERATING LOGICS
- SEMI - AUTOMATIC LOGIC
- AUTOMATIC LOGIC
A start impulse opens the gate. A second impulse during the opening stops the movement, a successive
impulse restarts the movement in closing. When the gate is in opening position a start
impulse is required for closing it again.
A start impulse in closing phase reverses the movement.
Note: Rotate the trimmer Rv3 completely clockwise.
A start impulse opens the gate. A second start impulse while the gate is opening is not accepted.
An impulse during the pause is not accepted. An impulse in closing phase reverses the movement.
- SAFETY AUTOMATIC LOGIC
A start impulse opens the gate. A second impulse in opening phase reverses the movement.
A start impulse during the closing phase reverses the movement.
- SAFETY SEMI - AUTOMATIC LOGIC
A start impulse opens the gate. A second impulse in opening phase reverses the movement.
When the gate is in opening position another impulse is required in order to reclose the gate.
A start impulse during the closing phase reverses the movement.
NB: Ruotare il trimmer Rv3 tutto in senso orario
OFF
FUNCTIONING LOGICS SELECTION (DIP1 E Rv3)
DIP1 po Trimmer Rv3 to select semi - automatic logic
Rv3
MAX
ON
OFF
DIP1 position to select the automatic logic
DIP1
DIP1 position to select the safety automatic logic
MAX
ON
DIP1 po Trimmer Rv3 to select the safety semi - automatic logic
SWING 2
25
DIP
1
2 3 4 5 6 7 8
ON
DIP
Rv3
Rv3
+
-
+
O
N
O
N
Rv3
MAX
11
11
11
+
Rv3
MAX
11
PROGRAMMING LOGICS: SUMMING UP TABLE
OPERATING LOGICS (DIP-SWITCH)
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
REV 07 - 05/2009