START, PEDESTRIAN START, STOP, ANTENNA
PHOTOCELLS 1 AND 2,
ELECTRIC LOCK
Start
This entry manages the opening/closing of the
automation.
Pedestrian Start
It executes complete opening/closing of one only leaf.
Note
: The partial opening is executed on motor 1.
Photocell S
elftest
* o
p
ti
o
n
al
Antenna
Connect
the
antenna as
in the
picture.
Stop
The pressure of this button
stops the automation at any
time. A START impulse is
required in order to re-
establish the movement.
If not used put a jumper
between contact 3 and 2 of
CN1.
2 shield
28
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
REV 07 - 05/2009
Photocells 1 Connection
When the photocells beam is crossed, the automation
reverses its movement if in closing phase.
To use the photocells self- testing connect the (+) of the TX
photocell 1 with contact 11 instead of 10.
Note: When not used make a jumper between contact 7
and 2 of Cn1.
Note: With the PALM device it is possible to set this
photocell as PHOTOCLOSE, that means, that if occupied
during the pause, the automation interrupts the same and
recloses immediately.
+ = 24V - = 0V C = Contact Com = Common
Photocells 2 Connection
When the photocells beam is crossed, the automation reverses
its movement if in closing phase. In opening it causes the stop
of the gate until it is occupied, when released the gate returns
into open postion.
Note: When not used make a jumper
between contact 6 and
2 of Cn1.
Note: With the PALM device it is possible to set as
PHOTOSTOP, that means that it does not allow to the gate
to open, while it does not intervene during the remaining
opening.
+ = 24V - = 0V C = Contact Com = Common
Electric lock
Note:
it’s possible to connect
only one
electric lock.
12V
15VA max