Control Button Use (from standby)
Set purge level
, 1-5 (1 is minimum, 5 is maximum) or Automatic:
•
Hold off button in for 3 seconds. Release.
•
Press and release the On button to cycle through and select one of the five purge settings
or to use the Automatic setting.
Recall diagnostic code
:
•
Hold off button in for 3 seconds. Release.
•
Press and release the Harvest button to cycle through each of the last 10 error codes from
most recent to oldest.
Clear diagnostic code:
•
Hold Clean and Harvest buttons in for 3 seconds to clear all prior codes.
Reset control:
•
Depress and release Off, then depress and release On
Start Test Mode:
•
Hold Off button in for 3 seconds. Release.
•
Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
•
Hold On button in for 3 seconds, keep holding then press and release Off twice.
Empty reservoir
:
•
Hold Clean button in for 3 seconds. Release. Pump and purge valve will be ON for 30
seconds. Repeat as needed.
Test Mode:
See next page for Air and Water Cooled mode.
•
Depress Off for 3 seconds, release. Then depress Clean for 3 seconds.
•
The sump will fill the first 30 seconds of the test. If the sump is full it will overflow into the
bin. At 30 seconds the WIV will shut off and the WP will turn on. You will be able to see
and hear the water running over the plates. After 10 seconds the PV and HGV will turn
on. Water will be purging from the machine. After 10 more seconds the compressor will
start. 5 seconds later the HGV will close. The compressor will run for a total of 20
seconds. After which everything will turn off for 5 seconds. After that time the HGV will
open and you’ll be able to hear the hissing as the pressure is equalized. 10 seconds later
the fan will turn on (if air cooled and fan control jumped). After 10 seconds all will be off
and the output test will be complete.
September 2006 Page 40