Product Description and Electrical Requirements
- See spec sheet or User's Manual for Minimum Circuit Ampacity or Maximum Fuse SIze
Dimensions
w” x d” x h”
Model
Electrical
Use condenser
22 x 24 x 23
C0522SR-1
115/60/1
ERC111-1
same
same
same
ERC211-1**
30 x 24 x 23
C0530SR-1
115/60/1
ERC111-1
same
same
same
ERC211-1**
same
C0630SR-32
208-230/60/1
ERC311-32
30 x 24 x 29
C0830SR-32
208-230/60/1
ERC311-32
same
C0830SR-3
208-230/60/3
ERC311-32
same
C1030SR-32
208-230/60/1
ERC311-32
same
C1030SR-3
208-230/60/3
ERC311-32
48 x 24 x 29
C1448SR-32
208-230/60/1
ERC311-32
same
C1448SR-3
208-230/60/3
ERC311-32
same
C1848SR-32
208-230/60/1
ERC611-32
same
C1848SR-3
208-230/60/3
ERC611-32
same
C2148SR-32
208-230/60/1
ERC611-32
same
C2148SR-3
208-230/60/3
ERC611-32
** ERC211 has two circuits, when two C0522s or C0530s are connected to it, fan motor relay
kit KCMR120 must be used to control the fan motor.
Ratings include the remote condenser motor, as it is designed to be powered by the ice
machine. If connecting remote condenser independently of the ice machine, use the
information on the condenser's dataplate for fuse and wire sizes.
Table notes: Medium cube models have the same electrical characteristics as Small. Series
revision code omitted. All the listed condensers include a headmaster valve.
September 2006 Page 10
General Installation - Remote