Water purge setting
The water purge is factory set to the Automatic setting. The setting can be changed to one of 5
manual settings or placed on automatic. The purge setting shows in the Code Display.
purge
setting
1 -
Minimum
2 -
Moderate
3 -
Standard
4 -
Heavy
5 -
Maximum
A - Automatic
Water
Type
RO water
or
equivalent,
TDS less
than 35
Low TDS
non - RO
water
Setting
for typical
water
High
TDS
water
Very high
TDS water,
greater than
256
Any with
conductivity
not less than
10
microSiemens/
cm
To set:
Switch the machine OFF by holding the Off button in until a number or the letter
A
shows on
the display.
Press and release the On button repeatedly until the number on the display corresponds to the
desired setting.
Press and release the Off switch again to return to the normal control state.
September 2006 Page 8