General Installation - Remote
Location Limitations
This ice system is made up of three parts, the ice making machine, or head; the remote
condenser; and the interconnecting tubing. The ice making machine must be installed indoors,
in a controlled environment. Space must be provided near the machine for service access. The
remote condenser may be installed above or below the ice machine, per the limits stated later
in this manual. The remote condenser may be installed outdoors within the temperature limits
listed below. The interconnecting tubing must be installed per the directions stated in this
manual, and the amount of tubing exposed to uncontrolled temperatures must be minimized.
Space Limitations
Although the machine will function with no clearance to the top and sides, some space must be
allowed for service access. Building the machine in with no access will cause higher service
cost, in many cases this extra cost may not be covered by warranty.
Environmental Limitations, ice machine:
Minimum
Maximum
Air temperature
50
o
F.
100
o
F.
Water temperature
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Environmental Limitations, remote condenser
Minimum
Maximum
Air temperature
-20
o
F.
120
o
F.
Power Supply
Minimum
Maximum
115 volt model
104 volts
126 volts
208-230 volt model
198 volts
253 volts
Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for
applicable coverage. In general warranty covers defects in material and workmanship. It does
not cover maintenance, corrections to installations, or situations when the ice machine is
operated in circumstances that exceed the limitations printed above.
September 2006 Page 9