![Scotsman C0522SR-1 Technical Manual Download Page 56](http://html.mh-extra.com/html/scotsman/c0522sr-1/c0522sr-1_technical-manual_1218679056.webp)
Makes Excessive Noise - Remote
Fan blade vibrates
Blade is bent
Replace fan blade
Fan motor mount is broken
Replace motor mount
Compressor vibrates
Mounting bolts loose
Tighten bolts
Water pump vibrates
Pump bearings worn
Replace pump
Panels vibrate
Mounting screws loose
Tighten screws
Test Mode Sequence - Remote
Test Time (seconds)
On
Off
0
WIV - 30 seconds
WP, HGV, Comp, BV, PV
30
WP - 10 seconds
WIV, HGV, Comp, BV, PV
40
WP, PV, HGV - 10
seconds
WIV, Comp, BV
50
HGV, Comp - 5 seconds
WIV, WP, BV, PV
55
Comp - 15 seconds
WIV, HGV, BV, WP, PV
70
None - 5 seconds
All
75
HGV - 5 seconds
WIV, WP, Comp, BV, PV
80
BV - 5 seconds
WIV, HGV, WP, Comp, PV
85
None
All – Test Complete