Purge valve
1
Push and hold the Off button to shut the
machine off.
2
Disconnect electrical power.
3
Remove front panel.
4
Remove left side panel.
5
Unplug wires from valve coil.
Note: The coil can be removed from the valve body by rotating it 1/8 turn
CW. After removal of the coil the spring and plunger can be taken out.
6
Remove screws holding valve to mounting bracket.
7
Remove inlet and outlet hoses
8
Remove valve from cabinet.
9
Reverse to reassemble
1
Push and release the On button to restart the machine
Water level sensor
1
Push and hold the Off button until the machine shuts off.
2
Remove the front panel.
3
Remove the sound shield.
4
Locate water level sensor.
5
Squeeze the locking tabs together and pull the sensor up
and out of the sump.
6
Unplug the electrical connection from the sensor.
7
Reverse to reassemble.
September 2006 Page 110
Repair Procedures
Electrical Shock Hazard.
Disconnect electrical
power before beginning.