Resistance reading tolerance is +- 10%
Ice Machine
Voltage/Hz/Phase
Compressor
Start Winding Ohms
Run Winding Ohms
C0330-1
115/60/1
AKA9438ZXA
4.22
.59
C0330-6
230/50
AKA9438ZXC
7.11
2.69
C0330-32
208-230/60/1
AKA9468ZXD
10.43
1.77
C0530-1
115/60/1
AKA9451ZXA
5.95
.69
C0530-6
230/50
AKA9451ZXC
7.11
2.69
C0530-32
208-230/60/1
AKA9451ZXD
10.43
1.77
C0630-32
208-230/60/1
AJA7490ZXD
2.74
1.52
C0630-6
230/50
AJA7490ZXC
2.23
2.02
C0830-32
208-230/60/1
CS10K6EPFV
3.10
1.16
C0830-6
230/50
CS10K6EPFJ
3.79
1.39
C0830-3
208-230/60/3
CS10K6ETF5
-
1.77
C1030-32
208-230/60/1
CS12K6EPFV
3.10
1.16
C1030-6
230/50
CS12K6EPFJ
3.79
1.39
C1030-3
208-230/60/3
CS12K6ETF5
-
1.77
Refrigerant Charges
October 2006 Page 62
Compressor Electrical Chart
Model
R-404A in
ounces
C0322A
14
C0322W
11
C0330A
14
C0330W
11
C0522A
17
C0522W
14
C0522R
160
C0530A
22
C0530W
11
C0530R
160
C0630A
36
C0630W
14
C0630R
160
C0830A
46
C0830W
34
C0830R
208
C1030A
48
C1030W
38
C1030R
208
C1448A
62
C1448W
56
C1448R
256
C1848A
62
C1848W
63
C1848R
320
C2148W
69
C2148R
320