Central Condenser Coils
The ice machine may be connected to a central condenser coil. The requirements are:
•
Coil – not previously used with mineral oil system. Virgin coil preferred.
•
Correct size (internal volume) and capacity (BTUH).
•
Includes a headmaster valve for discharge pressure control. Headmaster kit available for
certain MAC condensers, kit number is
RCKCME6GX
.
•
Fan motor on all the time or controlled to be on whenever the ice machine is operating.
•
Non-Scotsman condensers must have prior Scotsman Engineering approval for warranty
coverage to be in effect.
Precharged tubing kits:
The ice making head’s and the remote condenser’s refrigeration circuits must be connected.
They are designed to be connected using precharged refrigerant tubing, supplied in kits of
liquid and discharge tubes. Several lengths are available, order the one that just exceeds the
length needed for the site.
10”
25’
40’
75’
RTE10
RTE25
RTE40
RTE75
No additional refrigerant is required. Note: Refrigerant charge is supplied with the ice machine.
January 2009 Page 11
General Installation - Remote