3-12. ENGINE/FU SE LAGE/ELEC TRI CAL FIRE ON THE
GROUND.
Pull mix ture con trol to IDLE CUT OFF.
Set fuel shut off valve in CLOSED po si tion.
Set bat tery switch in OFF po si tion.
Set al ter na tor switch in OFF po si tion.
WARNING
RE MAIN CLEAR OF ROTOR BLADES DURING
AND AFTER EVAC U A TION.
Exit air craft with fire ex tin guisher.
3-13. ENGINE/FU SE LAGE FIRE, OR FIRE OF UN DE TER MINED
OR I GIN, IN FLIGHT - LOW/CRUISE AL TI TUDE.
Note: If a fire is ob served dur ing flight, pre vail ing con -
di tions such as day/night, al ti tude, and avail able land -
ing ar eas must be con sid ered in or der to de ter mine
whether to ex e cute a power-on or power-off land ing.
Power-on land ing:
Main tain air speed and ro tor RPM; be pre pared to per form a full
auto ro ta tion at any point in the ap proach.
Im me di ately per form power-on land ing to suit able area.
If time per mits:
Set bat tery switch in OFF po si tion.
Set al ter na tor switch in OFF po si tion.
Set cabin heater switch in OFF po si tion.
Emergency Procedures
SCHWEIZER
Model 269C Helicopter
Pilot's Flight Manual
Reissued:
16 Jan 2019
3-9
////
////
////
////
////
////
////
////
////
////
////
////
////
//
This Document contains technical data subject to EAR. See WARNING and classifications on first page.
FAA Approved
CSP Book 1 CSP-C-1.indd 79
8/4/19 12:45 PM