10 Quality monitoring
SCHMIDT
®
PressControl 3000 – V1.3
43
10 Quality
monitoring
10.1 Curves
The press system records the individual force and stroke data during the
pressing process. This data is then represented as a force curve in a
force/stroke diagram.
Select the "Curve Output" system function key.
2.00
1.50
1.00
.500
0.0
F[kN]
s[mm]
9.17
18.34
27.52
36.69
Figure 10-1: Curve Output
Curve display
You can modify the display of the curves in the "Curve Output" display
mode. These settings are made in the "Diagram selection" menu.
Select the "Curve Output" system function key.
Press the "Enter" key.
Select the "Diagram Mode" command.
1
CtrON
CtrOFF
...
...
Servic
Diagram Selection
Output Diagram Single
Diagram Force/Stroke
Units Metric
Figure 10-2: "Diagram Selection" menu
By default, when the curve output is called, only the last recorded curve is
displayed (parameter "Output Diagram" = "Single"). Alternatively, you can
also establish that the curves of the production process be displayed as a
group.
Activating
curve output
Curve output