5 Data Input
SCHMIDT
®
PressControl 3000 – V1.3
21
1
CtrON
CtrOFF
...
...
Servic
0
Access Code
Access
Com Port
Access
System Options
Access
Monitoring Data
Access
User Data
Access Codes
Figure 5-2: "Access Codes" submenu
Select the "Access Code" command.
Assign a new access code. This code consists of a number with a
maximum of 9 digits.
Select the access area which you would like to change.
Confirm the selection with the "Enter" key. The setting is changed from
"Access" to "No access" or visa versa.
Other features
These settings are made in the "System Options" display mode.
In the "System Options" submenu, select the "Date/Time" selection.
Select the "Date" command and enter the date in the format
"DD.MM.YY".
Select the "Time" command and enter the date in the format
"HH.MM.SS".
You can define two alarm times (Time Alarm 1 and Time Alarm 2) that
trigger an alarm daily. You further have the possibility to define an alarm
time (Time Alarm 3) that is only triggered on a certain date (Date Alarm 3).
In the "System Options" submenu, select the "Date/Time" selection.
Select the desired alarm in the "Alarm" menu.
Enter a time in format "HH.MM.SS" and the date in format "DD.MM.YY".
When the set alarm time is reached, a marker is activated in the PLC
program. By querying this marker, you can initiate other actions. For further
information, please see the "User manual - SCHMIDT
®
ControlTool - Part 2".
You can set the volume of the "key click" (acknowledgement when a key is
pressed) and the volume of the alarm functions. You can enter values of "0"
to "255" for both volumes.
Test the volumes under the usual background noise conditions to check if
the alarm can be heard during normal production operations.
Changing access code
Changing access
authorization
Date + time
Alarms
Volume