5 Data Input
SCHMIDT
®
PressControl 3000 – V1.3
20
Confirm the entry of the parameters by pressing the “Graphic init” key.
UE470 address
The CAN gateway address must be correctly set for the communication
between the control unit and the SCHMIDT
®
SafetyModule. The address
“10“ is set by default in the CAN gateway and also in the control unit.
Select the “System menu” system function key.
Select the “Service” submenu in the “System Options” menu.
1
CtrON
CtrOFF
...
...
Servic
Adress UE470 10
Ident
Service
Figure 5-4: UE470 address
The address is set in the CAN gateway by means of two rotary switches.
Access
Assigning an access code and privilege level
The control is delivered ex works with complete access rights and with the
access code "0".
Limit access to the individual areas.
Assign a new access code. This code consists of a number with a
maximum of 9 digits.
These settings are made in the "System Options" display mode.
Select the "System Options" system function key.
Select the "Access Codes" menu.
Enter the access code (default setting = "0").
CAUTION
!