7 Press processes
SCHMIDT
®
PressControl 3000 – V1.3
32
•
min. force limit
•
max. force limit
•
min. stroke limit
•
max. stroke limit
Select the “Block-Limit-Window" parameter.
Enter the value “1”. Enter value “0” to deactivate the function.
7.3 Acknowledging
an
incorrect pressing
An incorrect pressing can be acknowledged by pressing the "ACK" softkey.
Change to operating level 2.
Press the "ACK" softkey.
or
Press the "Acknowledge incorrect pressing" key.
Acknowledging by means of external luminous button
In addition to the options of acknowledging an error described above, for
severe production conditions, an external luminous button can be used to
acknowledge an incorrect pressing.
Connect the external luminous button for acknowledging incorrect
pressing to the relevant input (see circuit diagram) of the SCHMIDT
®
SafetyModule.
Now the error messages can also be acknowledged using the external
luminous button.
If you want to acknowledge error messages exclusively by means of the
external luminous button, you have to switch on additionally the “ACK n.ok-
box on/off” parameter.
Select the "Data Input" system function key.
Select the " ACK n.ok-box on/off" parameter.
Enter the value "1". To switch the function off again, enter the value "0".
Switching on
Acknowledging via
luminous button only