8 Further integrated functions
SCHMIDT
®
PressControl 3000 – V1.3
37
Servic
...
...
CtrOFF
CtrON
1
40.432 mm
2138 N
Reached stroke :
Reached force :
21 pcs
4 pcs
17 pcs
Quantity :
Quantity nok :
Quantity ok :
30.000 mm
Returnstroke at stroke:
2-Hand-Release
Machine ok.
PC-DEAC
Dataset 1
( )
1
Figure 8-2: View of "Output 1" including the note "PC-DEAC"
When operating the control on an external PC using SCHMIDT
®
ControlTool
software, a press stroke is only possible if the PressControl 3000 is
connected to ControlTool. If there is no connection, the stroke will be
blocked.
Select the "Data Input" system function key.
Select the "PC on/off" parameter.
Enter the value "1". To switch the function off again, enter the value "0".
As long as no connection has been established to the PC, the stroke
remains blocked. In addition, the control displays "! PC not ready !".
Servic
...
...
CtrOFF
CtrON
1
40.432 mm
2138 N
Reached stroke :
Reached force :
21 pcs
4 pcs
17 pcs
Quantity :
Quantity nok :
Quantity ok :
30.000 mm
Returnstroke at stroke:
! PC not ready !
SPC-OFF
PC-OFF
Dataset 1
( )
1
Figure 8-3: View of "Output 1" including the note "! PC not ready !"
Configure the press system in the SCHMIDT
®
ControlTool software
(see section "Define press unit" in the "User Manual - SCHMIDT
ControlTool - Part 1").
Establish the connection (see chapter "4.1 Establishing a connection to
the control" in the " User Manual - SCHMIDT
®
ControlTool - Part 1").
Select the “Data Input” system function key.
Select the "SPC on/off" parameter.
Configuring the press
SCHMIDT
®
ControlTool
Establishing a
connection
Switching on the SPC