Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 105
11.3.1 Cold weather operation
Observe the motor manufacturer's operating
instructions for winter operation of the auxiliary
engine.
Drain the compressed air tank for controlling
the machine (located under the water tank) daily.
Check fluid level and anti-freeze in radiator.
Carry out the following frost prevention measures
on the water system after use:
o
Drain water tank.
o
Drain water filter.
o
Blow out water lines with compressed air.
11.3.2 Reversing
When the vehicle is put into reverse, you will hear
a warning signal. The sweeper and pick-up unit
are automatically raised when the auxiliary engine
is switched on.
NOTE
Damage to the pick-up unit
►
Do not travel or roll in reverse with the
pick-up unit lowered
NOTE
Damage to the blowing unit due to higher objects
►
When the blowing unit is lowered, carefully
drive around higher objects, such as kerb
stones, street boundaries, etc. or lift the
blowing unit
11.3.3 Debris suction operation with disc
brush
WARNING
Injury due to malfunctioning brush system
►
Do not stand on the disc brushes or transport
people on them
WARNING
Snagging, winding up or puncturing caused
by moving brushes
►
Stop working immediately if people enter
the danger area, and stop the machine
WARNING
Impacts due to raising, lowering and pivoting
the brush
►
Stop working immediately if people enter
the danger area, and stop the machine