Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 166
22.10 Electrohydraulics
Changing the oil and cleaning
the oil strainer
22.10.1 Removing the oil
Warm the hydraulic fluid to approximately 50°C
by moving the snow plough (raising, lowering,
pivoting).
Park the vehicle safely.
Unscrew the filler cap with oil dipstick (1).
Suck out the oil with suction equipment (2).
Put the suction nozzle (3) into the filler opening
and suck out the oil.
22.10.2 Draining oil
Place the oil capture container under the electro-
hydraulic pump.
Carefully loosen the tank by loosening the
4 screws (1) until oil flows out between the
pump flange and the oil container.
Remove the tank
Clean the tank, especially the magnets that are
in the tank.
Reinstall the tank. Ensure that the sealing surface
is clean and that the sealing ring has been lightly
oiled.
22.10.3 Fill the hydraulic equipment with oil
Fill with oil (approximately 5 litres) using the filler
opening (1).
Check oil level using the dipstick (2). The oil must
be between the markings (3) when the hydraulic
cylinders are retracted.
Turn on the hydraulic equipment and carry out
all hydraulic functions. Check oil level again.
Repeat the procedure until the oil level no longer
changes.
1
2
3
1
1
2
3