Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 125
Blowing equipment has moved
Hinges sticking: Clean and oil
Pneumatic cylinder defective.
Valves do not switch.
Malfunctions on the auxiliary engine
See engine manufacturer's operating instructions
Engine not starting
EMERGENCY STOP button activated and locked
Unlock switch.
Fuel line damaged
Defective
battery
Defective starter motor
Defective
controls
Coolant temperature too high
Engine oil pressure too low
Compressed air supply less than 5.5 bar,
carbamide system
15.1 Pneumatic
system
Faults Causes/remedy
Air pressure in HGV braking system
too low
Defective HGV pneumatic system.
Pneumatic valve for draining the water system
open
Defective electrical controller - check valves
by operating manually.
Loss of compressed air in the system
(loose connections, hoses damaged).
Operating cylinder insufficient or
not functioning.
Pneumatic valve for draining the water system
open
Defective electrical controller - check valves
by operating manually.
Loss of compressed air in the system
(loose connections, hoses damaged).
Engine can be started however
than switches off again
Compressed air supply too low for carbamide
system
15.2 Hydraulic
system
Faults Causes/remedy
Operating cylinder not working
Defective electric controller—check valves
through manual operation.
Note
: This check can only be carried out if the
auxiliary valve is also activated at the same
time through manual operation.
Check valve block operating pressure
(Rated = 150 bar)
.