Translation of Original Operating Instructions
Airport Sweeper / Airport Stand Cleaner
2017-02-02 158
22.2 Changing disc brushes
NOTE
Loosen the screw connection of the brush
fastening
►
At every brush change, use new self-locking
nuts
Disassembly
Lower disc brush.
Depressurise the pneumatic system.
o
Switch off the vehicle engine to shut down
the air feed to the pneumatic tank.
o
Actuate the drain valve on the pneumatic
tank until the tank is empty.
Loosen the eight screws and self-locking
nuts (1).
Raise disc brush.
Dispose of disc brush correctly.
Installation
Assembly is carried out by reversing the process.
Only new self locking nuts are to be used to
fasten the disc brushes
After installing, the vehicle engine is to be started
so that the air supply is re-established for the
pneumatic system. The sweep range must be
set again.
22.3 Grease the brush drive universal
joint
DANGER
Crushing
►
Maintain a sufficient distance
The pneumatic cylinder extends when the ball
valve (1) on the coupling plate is closed.
There is a universal joint on the right hand side of
the brush drive.
Lubricate universal joint
Lower or raise the pick-up unit and secure it
with transit locks.
Parking the machine safely
At the coupling plate (1), close the air supply from
the HGV for the cylindrical brush function with the
ball valve. Air in the pneumatic cylinder escapes
through the ball valve. The cylindrical brush
lowers in the pick-up unit down to the stopper.
Take out (2) the fastening screw (SW 13)
Pull the brush extension with the hydraulic
motor (3) out of the spline shaft until access
to the grease nipple (3) can be obtained.
1