48
2021-02-10 / V1.0
Maintenance
Contactors C195 Series – Installation and Maintenance Instructions
Disassembling/assembling the armature –
type C195 A/, B/, S/, T/, W/
Requirement
The contact unit is disassembled, see section
“Disas-
sembling/assembling the contact unit – type C195 A/,
B/, S/, T/, W/” on page 46.
Disassembly
X
Pull the armature (4) at the bottom of the contact
unit and unhook the armature (4) laterally from
the contact bridge unit (5).
5
4
Fig. 57: C195 A/, C195 B/: Disassembling the armature
(the figure shows C195 A/, the procedure is identical
for C195 B/)
5
4
Fig. 58: C195 S/, C195 T/: Disassembling the armature
(the figure shows C195 S/, the procedure is identical
for C195 T/)
5
4
Fig. 59: C195 W/: Disassembling the armature
Assembly
X
Press in the auxiliary switch actuator (6) on the
cover (7) and keep it pressed.
X
With the auxiliary switch actuator (6) pressed,
hook the armature (4) laterally into the contact
bridge unit (5).
7
6
5
4
Fig. 60: C195 A/, C195 B/: Assembling the armature
(the figure shows C195 A/, the procedure is identical
for C195 B/)
5
4
7
6
Fig. 61: C195 S/, C195 T/: Assembling the armature
(the figure shows C195 S/, the procedure is identical
for C195 T/)