20
2021-02-10 / V1.0
Installation
Contactors C195 Series – Installation and Maintenance Instructions
7.1.8 Installing the contactor
X
Ensure that the contact surfaces on the mounting
plate (3) or frame and the bottom of the contac-
tor are free from dirt and other contamination (e.g.
metal chips).
X
Position the contactor (1) on the mounting plate/
frame (3) which is provided with mounting holes.
X
Screw the contactor (1) on the mounting flange
to the mounting plate/frame (3) using mounting
screws (2) according to the table below.
-
In designs with the mounting holes imple-
mented as threaded holes, screw the mounting
screws into the holes directly, not forgetting the
suitable screw locking elements.
-
In designs with through holes, fit the mounting
screws and suitable screw locking elements (on
both sides) and tighten the screws using nuts.
X
Tighten the mounting screws to the specified
torque, which depends on the strength class (min.
8.8) of the screws/nuts used.
Type
Mounting screws
No. of screws
C195 X/
M8
2
C195 A/
M6
3
C195 B/
M6
3
C195 S/
M6
2
C195 T/
M6
2
C195 W/
M6
2
3
2
1
Nm
M8
2
Nm
M8
Fig. 14: C195 X/: Installing the contactor on the mounting
plate or frame
3
2
1
Nm
2 x M6
2
Nm
M6
Fig. 15: C195 A/: Installing the contactor on the mounting
plate or frame (the figure shows C195 A, the proce-
dure is identical for C195 B/)
3
2
1
Nm
M6
2
Nm
M6
Fig. 16: C195 T/: Installing the contactor on the mounting
plate or frame (the figure shows C195 T, the procedure
is identical for C195 S/)
3
2
1
Nm
M6
2
Nm
M6
Fig. 17: C195 W/: Installing the contactor on the mounting
plate or frame