18
2021-02-10 / V1.0
Installation
Contactors C195 Series – Installation and Maintenance Instructions
7. Installation
7.1 Mounting
7.1.1 Dimensions/interfaces and further
technical specifications
The dimensions and other technical specifications are
given in the respective data sheets or can be found in
our
B195 catalogue
. The
catalogue
is available under:
https://www.schaltbau.com/en/media-library/
7.1.2 Preparatory measures
X
A suitable mounting plate or frame must be pro-
vided for fastening of the contactors. These must
be sufficiently stable to support the weight of
the contactors under the expected vibration and
shock conditions.
X
Mounting holes must be prepared on the mount-
ing plate or frame according to the following di-
mensional drawings (
Fig. 9 to Fig. 11
).
Ø
9 or M8
Ø
9 or M8
18
2
±
0.2
[mm]
Fig. 9:
C195 X:/ Dimensions and layout of mounting holes
20
128
±
0.2
2x Ø
6.6
or M6
[mm]
Ø
6.6 or M6
Fig. 10: C195 A/, C195 B/: Dimensions and layout of mounting
holes
Ø
6.6 or M6
93
Ø
6.6 or M6
[mm]
Fig. 11: C195 S/, C195 T/, C195 W/: Dimensions and layout of
mounting holes
X
The mounting holes can be either:
-
threaded holes (for threaded screws)
-
or through holes (for threaded screws and nuts)
X
The size and number of mounting screws depend-
ing on the type of contactor can be found in the
table under
“7.1.8 Installing the contactor” on
page 20
.
X
The length of the mounting screws must be deter-
mined dependent on the structural circumstances.