PROBLEM
POSSIBLE CAUSE(S)
SOLUTION
The motor will not
start and both status
lights on the switch
box are off .
There is no power to the saw.
Make sure the electrical supply to
the saw is on and that the correct
voltage is being supplied.
There is no brake cartridge
installed in the saw.
Install the brake cartridge (
see
page 34
).
The brake cartridge is defective.
Replace the brake cartridge with a
new cartridge (
see page 34
).
The motor will not
start: the power
switch is on, the red
status light on solid,
the green status light
is off (
see page 45
) .
The brake cartridge is defective.
Replace the brake cartridge with a
new cartridge (
see page 34
).
The motor starts
slowly and/or fails to
reach full operating
speed .
The electrical supply voltage is
too low.
Make sure the correct voltage is
being supplied to the saw.
The belt is worn or slipping.
Replace the belt.
The motor stopped
unexpectedly during
use but the brake did
not activate .
The Start/Stop paddle was
bumped.
Ensure the Start/Stop paddle is in
the OFF position, and then restart
the saw.
The material being cut is
overloading the safety detection
system (e.g., green or wet
wood).
Use a different wood or cut in
Bypass Mode (
see page 50
).
Electrical power to the system
was lost, at least temporarily.
Ensure that the electrical supply
to the saw is on and you are using
the correct voltage.
The brake cartridge is defective.
Replace the brake cartridge with a
new cartridge (
see page 34
).