![Savch S200 Series User Manual Download Page 68](http://html.mh-extra.com/html/savch/s200-series/s200-series_user-manual_1203756068.webp)
64
Braking resistor list
Voltage
Applicable
motor
Full load output
torque(Nm)
Applied
resistor
specification
Braking
unit
Quantity
Braking
torque
10%ED%
Min
resistance
HP
4P
kW
440V
series
1
0.75
4.187
80W 750
Ω
×
1
125
260
Ω
2
1.5
8.326
300W 400
Ω
×
1
125
190
Ω
3
2.2
12.376
300W 250
Ω
×
1
125
145
Ω
5
3.7
20.398
400W 150
Ω
×
1
125
95
Ω
7.5
5.5
30.508
500W 100
Ω
×
1
125
60
Ω
10
7.5
11.258
1000W 75
Ω
×
1
125
45
Ω
15
11
60.664
1000W 50
Ω
×
1
125
50
Ω
20
15
80.885
1500W 40
Ω
×
1
125
40
Ω
Notes:
1.
Watts of voltage value and frequency applied(ED %) shall be in accordance with specifications of this
company.
2.
This company shall not be responsible for damaging of inverter or other devices, which shall be caused by
braking resistor or braking module that were not produced by this company.
3.
When installing braking resistor, great care shall be given to safety or inflammability of the ambient
environments
4.
In case of Min resistance shall be used, contact your SAVCH ELECTRIC for suggestion of watts calculating.
5.
“○”Refers to that fixing braking unit is necessary.