DESCRIPTION OF FUNCTIONAL PARAMETERS
0 System parameters
00-00
Machine Model Recognition
Factory setting
Type Setting
Setting range
Display according to machine model
The parameter displays a drive’s model code. Capacity of the drive, rated current, rated voltage and Max. carrier
frequency are related to the setting model code . User may refer to the following table to check drive’s model.
Drive capacity
、
Machine type code
、
Rated Current:
440V Series Power kW
0.75
1.5
2.2
3.7
4.0
5.5
7.5
11
15
HP
1
2
3
5
5.4
7.5
10
15
20
Machine Model Recognition code
05
07
09
11
12
13
15
17
19
Rated Voltage
440V
Rated Current
3.0
4.2
5.5
8.2
9.7
13
18
24
32
Max carrier frequency
15kHz
00-01
Rated Voltage Display
Factory setting
Type Setting
Setting range
Display according to machine model
This parameter displays the rated output voltage of drive. User can view this parameter display value to check the
drive is correct or not..
00-02
Rated Current Display
Factory setting
Type Setting
Setting range
Display according to machine model
This parameter displays the rated output current of drive. User can view this parameter display value to check the
drive is correct or not.
00-03
Parameter Lock/Reset Setting
Factory setting
0
Setting range
0 All parameters set to read/write mode
1 All parameters set to read only mode
2~9 Reserved
10 All parameters reset to factory setting(50Hz)
This parameter is to remove alarm history; Cause some reasons or wildly set parameter leads to abnormal,
recover factory setting, then reset it.
Remove alarm history or recover factory setting, then the parameter will be reset to 0 automatically.