11 Special Parameters
11-00
Motor control method
Factory setting
1
Setting range
0:V/F control
1:V/F c Auto slip Compensation
2:Vector control
This parameter determines the control mode of the AC motor drive.
12 Special Parameters
12-00
Low voltage level (LU)
Factory setting
390
Setting range
320
~
440VDC
This parameter is used to set the LU standard.
12-01
Over voltage stall prevention level setting
Factory setting
720
Setting range 700
~
900V
When deceleration is performed, back-up energy may be generated in AC motor drive due to inertia of motor load,
and DC side voltage may rise to max value. Thus, when over voltage stall prevention is started, over voltage at
DC side shall be detected, and deceleration shall be interrupted (output frequency shall be kept), which will not be
performed again by AC motor drive until voltage is below setting value.
12-03
Automatic voltage regulator function(AVR)
Factory setting
0
Setting range 0:Start AVR