This parameter can be used to set the AC motor drive in start accelerated when make a soft start, the curve can
be in different degrees as settings vary from1 to 100. To start a slow accel/decel, the curve in different speed rate
shall be provided by the AC motor drive according to the orientated Accle/decel time.
05-11
Hopping frequency 1
Factory setting
0.00
05-12
Hopping frequency 2
0.00
05-13
Hopping frequency 3
0.00
Setting range
0.00
~
600.00 Hz
This parameter determines the three hopping frequencies, which in conjunction with 05-14 [Hopping frequency
width] will cause the AC drive to skip operation at these frequency ranges.
05-14
Hopping frequency width setting
Factory setting
0.10
Setting range
0.1
~
20.0 Hz
This parameter determines the frequency band of a given [Hopping frequency]. The actual band is 2 x Skip
frequency band, half of which is above and the other half is below the [hopping frequency] setting. Setting this
parameter to 0.1 to disable all hopping frequencies