4 Multi-step Speed and Program Operation Parameters
04-00
No.1 section of the frequency selection
Factory setting
0
04-01
No.2 section of the frequency selection
0
04-02
No.3 section of the frequency selection
0
04-03
No.4 section of the frequency selection
0
04-04
No.5 section of the frequency selection
0
04-05
No.6 section of the frequency selection
0
04-06
No.7 section of the frequency selection
0
Setting range 0
~
600.00Hz
The multi-function input terminals (refer to parameters 02-01,02,03) are used to select one of seven Multi-Speed
output frequencies. The frequency is determined by 04-00 to 06.
5 Special Parameters
05-00
DC braking current level setting
Factory setting
0
Setting range 0
~
100%
When AC motor drive stopped mode is set to decelerate and stop, this parameter setting brake into DC brake
motor current level. Set dc braking current composition ratio:1%. Ac motor drive current rating of 100%.
When this parameter is set, begin at a lower current level then increase the value until sufficient holding torque is
achieved. The rated motor current cannot be exceeded.
05-01
DC braking time setting at starting
Factory setting
0.0
Setting range
0.0
~
5.0 Sec
This parameter is to set time lasting of DC braking voltage input to motor during start of AC motor drive.
05-02
DC braking time setting at stopping
Factory setting
0.0
Setting range
0.0
~
25.0 Sec
When the AC motor drive stop method is set to ramp stop,this parameter is to set time lasting of DC braking
voltage input to motor during braking.
05-03
DC braking starting frequency at stopping
Factory setting
0.00
Setting range 0.00
~
50.00 Hz
This parameter is to set DC braking starting frequency from deceleration to stop of AC motor drive.
Unit:0.01Hz.When set value is below min frequency (1-07), starting frequency of DC braking shall begin from min
frequency.